The TH-828 Chiller is a refrigeration-based shoe cooling machine that rapidly reduces the temperature of freshly formed shoe uppers and bottoms — bringing them down to as low as -15°C within the same production cycle. Without a dedicated chilling stage, residual heat from steam forming or bottom-press operations causes deformation during last removal, undermining the shape accuracy the forming step was meant to achieve. The TH-828 Chiller addresses this directly by passing the lasted shoe through a refrigerated conveyor tunnel, locking the formed shape before the last is removed and returning each last to the production line faster.
For footwear factories running paired last sets, a shorter last occupancy time directly determines how many pairs can complete a shift without expanding the last inventory. The TH-828 Chiller is positioned between the forming and last-extraction stages in a cemented construction footwear production line, functioning as the shape-stabilization step that makes consistent last cycling possible.
The TH-828 Chiller is available in 3.2M, 3.8M, and 4.2M conveyor length configurations. Each variant shares the same refrigeration standard while scaling output capacity to match different production volumes and shift targets.
| Specification | 3.2M Model | 3.8M Model | 4.2M Model |
|---|---|---|---|
| Conveyor Length | 3.2 m | 3.8 m | 4.2 m |
| Overall Dimensions (L × W × H) | 2500 × 900 × 1700 mm | 3200 × 900 × 1700 mm | 4500 × 900 × 1700 mm |
| Power Input | 4 kW | 4.5 kW | 7 kW |
| Voltage | 380V / 50Hz | 380V / 50Hz | 380V / 50Hz |
| Net Weight | 550 kg | 550 kg | 550 kg |
| Output Capacity | 1,200 pairs / 8 hr | 1,800 pairs / 8 hr | 2,500 pairs / 8 hr |
| Temperature Range | Ambient to -15°C | Ambient to -15°C | Ambient to -15°C |
All three TH-828 Chiller models operate on a 380V three-phase 50Hz electrical supply — the standard industrial voltage for footwear factory infrastructure in most manufacturing markets. Buyers planning installations in regions with non-standard voltages should confirm local electrical compatibility before finalizing the order. The 4.2M model draws 7 kW — approximately 75% more than the 3.2M variant — a difference that should be factored into the factory's electrical load planning when adding the TH-828 Chiller to an existing circuit.
The TH-828 Chiller incorporates specific design choices that translate directly into daily production reliability and output consistency.
Spec sheets for the TH-828 Chiller list temperature rating and power consumption, but what matters in a continuous production environment is whether temperature uniformity holds across a full eight-hour shift without climate control. The TH-828 Chiller is specified for uniform temperature distribution across the conveyor width, supporting consistent shape retention at both center and edge positions throughout the shift.
The TH-828 Chiller is designed for three primary scenarios in footwear manufacturing operations:
Selecting the right TH-828 Chiller model means matching the conveyor length to available floor space, not just to the rated output. The 4.2M model requires 4,500 mm of floor length plus infeed and outfeed clearance for operator access. A larger TH-828 Chiller with higher rated capacity may not be the right choice if the factory floor plan requires a routing workaround around fixed infrastructure — the handling time and ergonomic cost of that workaround can offset the rated capacity advantage within a single production season.
Factory owners specifying the TH-828 Chiller should confirm the following before selecting a model:
The TH-828 Chiller is designed for simple operation and easy maintenance, which supports faster operator onboarding and reduces skill-level dependency in facilities with high turnover. For footwear factories that have integrated steam forming or bottom-press operations and need a reliable cooling stage to complete the shape-locking cycle, the TH-828 Chiller is available in three documented production-scale variants to match line output and floor space requirements.